    Brand Name : Air Giant
    Model Number : HMP80/20, HMP140/20, HMP80/30, HMP140/30
    Certification : CAL,CMA,CNAS,ILAC-MRA,CCC
    Price : negotiation
    Payment Terms : L/C , D/P, T/T, Western Union, Paypal, Credit card
    Supply Ability : 300 sets per week
    Delivery Time : 10-15 working days
    • Product Details
    • Company Profile

    Cylinder For Inert Gas Inergen IG541 Fire Extinguishing System Without Residue In Server Room

    Cylinder For Inert Gas Inergen IG541 Fire Extinguishing System Without Residue For Server Room


    IG541 mixture gas (52% nitrogen, 40% argon, 8% carbon dioxide) is a kind of colorless and tasteless and nontoxic and non-conducting, pure “green” gas without residue and pollution after extinguishing. And ODP of it is zero. It is a friendly-environment gas to be used for extinguishing. Also, because of such feature, it can be used in special place where electrical fire is easy to happen.


    Combined with extinguishing device and electronic accessories, the whole system can be actuated automatically. It can monitor the situation of protective region through detectors and then it can also start the extinguishing device through solenoid actuator automatically. So the whole system can achieve automation totally. Therefore, it can avoid that there is no one who notice the fire when it happens and it also saves much money for employment to supervise the protective area.


    Management of Multiple zones is also in the safe control of the whole system. We can use one system to protect multiple zones through distributing valves. It can make the whole system alternative aiming at different protective zone. Agent can be discharged into where the fire happens. It will be very efficient to put out fire in short time. One thing that need to mention, is that a little room should be prepare to be as storage space for the whole system.


    Parameters


    No.SpecificationIG541(52% nitrogen;40% argon,8carbon dioxide)
    1Capacity80Ltr140ltr
    2Working Pressure20MPa30MPa20MPa30MPa
    3Device ModelQMH20/80QMH30/80QMH20/140QMH30/140
    4Filling Capacity of Gas22.37kg33.56kg42kg58.2kg
    5Outside Diameter of CylinderΦ279mmΦ267mmΦ406mmΦ356mm
    6Height of Cylinder1710mm1870mm1460mm1925mm
    7Filling Rate0.299kg/L0.415kg/L0.300kg/L0.201kg/L
    8Spraying Time≤120s
    9PowerDC24V/1.6A
    10Nitrogen Pressure of Driving Device6.0±1.0MPa(20℃)
    11Condition of Reserving Room for Containertemperature: 0~50℃

    Features and benefits


    1. Compared with the traditional 15MPa system, the 30MPa system saves 25%-50% of the quantity of extinguisher cylinders.

    2. It effectively reduces the floor area between the cylinders and improves the overall use value and utilization rate of the building.

    3. Constant low pressure release of 6MPa reduces the cost of piping and components for the whole system.

    4. The constant release pressure of 6MPa provides a more durable and effective pressure, with a transmission distance of up to 200 meters.

    5. Whole system release by low pressure, it will be less impact on site personnel, equipment and building structure, and it will be more safety.

    6. The external constant pressure-relief device only bears the pressure when the system is discharged, which is convenient for disassembly and maintenance, and effectively reduces the system failure rate.

    7. After discharging, the system can be put into operation quickly with simple disassembly and secondary filling witn agent without replacing any parts.

    8. It reduces the area of opening hole of gas pressure relief port, directly reduces the input cost of safety pressure relief device, and installs and arranges safety buckle become more simply.


    Application


    Computer room, telecommunication room, transformer room, electrical switch and distribution room,

    generator room, leaching tank, drying equipment, paint spraying booth, electrical instrument room,

    control center, library, archives, treasure trove of cultural relics, etc.



    Package


    We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.


    Quality Cylinder For Inert Gas Inergen IG541 Fire Extinguishing System Without Residue In Server Room for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Air Giant Fire Equipment Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)