    Brand Name : Air Giant
    Model Number : DMP80/20, DMP140/20, DMP80/30, DMP140/30
    Certification : CAL,CMA,CNAS,ILAC-MRA,CCC
    Price : negotiation
    Payment Terms : L/C , D/P, T/T, Western Union, Paypal, Credit card
    Supply Ability : 300 sets per week
    Delivery Time : 10-15 working days
    • Product Details
    • Company Profile

    Cylinder For Inert Gas Nitrogen IG100 Fire Extinguishing System Without Pollution In Battery Room

    Cylinder for Inert Gas Nitrogen IG100 Fire Extinguishing System without pollution in battery room


    IG-100 uses Nitrogen for a clean, safe and 100% ecological extinguishing. This gas is widely used in variety of extinguishing systems due to its excellent pressurization conditions.


    In this case it complies with equal smothering efficiency by reducing the oxygen concentration to extinguish the fire, while leaving a percentage of oxygen suitable for occupied areas. Because of this feature, people can be protected where there is the possibility if they are in the enclosure area at the time of the fire, ensuring their safe evacuation both in terms of the level of oxygen in the room, and the absence of chemicals in the discharge. In addition, its physical and dispersion properties help maintain visibility during the evacuation.


    It is highly recommended for class A, B and C fires. The system operates by total flooding of the room, ensuring discharge in or less than 10 seconds with the safety conditions mentioned above. this makes it possible to adapt the quantity of extinguishing agent required, to the storage space available for the cylinders.


    The system is optimized for the worst case conditions, all components are certified to ensure the strictest performance. These are necessary for the storage, detection, release and discharge of the agent at the right moment.


    Parameters


    No.SpecificationIG100(100% nitrogen)
    1Capacity80Ltr140ltr
    2Working Pressure20MPa30MPa20MPa30MPa
    3Device ModelQMH20/80QMH30/80QMH20/140QMH30/140
    4Filling Capacity of Gas18.38kg27.57kg42kg58.2kg
    5Outside Diameter of CylinderΦ279mmΦ267mmΦ406mmΦ356mm
    6Height of Cylinder1710mm1870mm1460mm1925mm
    7Filling Rate0.299kg/L0.415kg/L0.300kg/L0.201kg/L
    8Spraying Time≤120s
    9PowerDC24V/1.6A
    10Nitrogen Pressure of Driving Device6.0±1.0MPa(20℃)
    11Condition of Reserving Room for Containertemperature: 0~50℃

    Features and benefits

    1. Compared with the traditional 15MPa system, the 30MPa system saves 25%-50% of the quantity of extinguisher cylinders.

    2. It effectively reduces the floor area between the cylinders and improves the overall use value and utilization rate of the building.

    3. Constant low pressure release of 6MPa reduces the cost of piping and components for the whole system.

    4. The constant release pressure of 6MPa provides a more durable and effective pressure, with a transmission distance of up to 200 meters.

    5. Whole system release by low pressure, it will be less impact on site personnel, equipment and building structure, and it will be more safety.

    6. The external constant pressure-relief device only bears the pressure when the system is discharged, which is convenient for disassembly and maintenance, and effectively reduces the system failure rate.

    7. After discharging, the system can be put into operation quickly with simple disassembly and secondary filling witn agent without replacing any parts.

    8. It reduces the area of opening hole of gas pressure relief port, directly reduces the input cost of safety pressure relief device, and installs and arranges safety buckle become more simply.

    9. IG55 fire extinguishing system can be widely used in important places that need rapid response to fire. There are workers, sudden fires and sensitive to chemical reactions on the site of the protection zone, the fire extinguishing system can effectively protect the safety of personnel and property.


    Application

    • DATA Centre
    • Comms Rooms
    • Telecommunication facilities
    • UPS Rooms
    • Medical facilities

    Package


    We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.

    Quality Cylinder For Inert Gas Nitrogen IG100 Fire Extinguishing System Without Pollution In Battery Room for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Air Giant Fire Equipment Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)